By continuing your navigation on this site, you accept the use of cookies in order to ensure the smooth running of your visit and to produce audience statistics.To find out moreI understand
SAUTER Building Information Modeling
Thermal actuator, 100-125 N -AXT 301, 311
Drives
How energy efficiency is improved
Reliable actuation in efficient control systems
Features
- Actuation of unit valves and valves in surface heating and cooling systems as well as fan coils
- Low-force fitting on the valve using adapter ring
- NC “normally closed” and NO “normally open” versions
- NC version with first-open function
- Adaptation to valve using plastic adapter M30 × 1.5 or M28 × 1.5
- Max. closing force 125 N
- With 230 V or 24 V thermal expansion element
- Large visible and tactile position indicator
- Low-noise and maintenance-free
- Contemporary design
- High functional quality and service life
- Version with integrated auxiliary contact
- Standard version with 1-metre cable permanently connected
- Version with 2 m or 5 m plug-in cable
- Can be mounted in any position, even suspended under the valve
Part # |
Voltage |
Stroke |
Closing Force |
Running Time |
NC/NO |
Cable Length |
Function |
CAD |
RFA |
Data Sheet |
---|---|---|---|---|---|---|---|---|---|---|
Part # N/A AXT301F110 | Voltage N/A 230 VAC | Stroke N/A 5.0 mm | Closing Force N/A 100 N | Running Time N/A 4.0 min | NC/NO N/A NC | Cable Length N/A 1 m | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301F112 | Voltage N/A 24 VAC/DC | Stroke N/A 5.0 mm | Closing Force N/A 100 N | Running Time N/A 4.0 min | NC/NO N/A NC | Cable Length N/A 1 m | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301F210 | Voltage N/A 230 VAC | Stroke N/A 5.0 mm | Closing Force N/A 100 N | Running Time N/A 4.0 min | NC/NO N/A NO | Cable Length N/A 1 m | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301F212 | Voltage N/A 24 VAC/DC | Stroke N/A 5.0 mm | Closing Force N/A 100 N | Running Time N/A 4.0 min | NC/NO N/A NO | Cable Length N/A 1 m | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301F100 | Voltage N/A 230 VAC | Stroke N/A 5.0 mm | Closing Force N/A 100 N | Running Time N/A 4.0 min | NC/NO N/A NC | Cable Length N/A Without cable | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301F102 | Voltage N/A 24 VAC/DC | Stroke N/A 5.0 mm | Closing Force N/A 100 N | Running Time N/A 4.0 min | NC/NO N/A NC | Cable Length N/A Without cable | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301HF110 | Voltage N/A 230 VAC | Stroke N/A 4.0 mm | Closing Force N/A 100 N | Running Time N/A 3.5 min | NC/NO N/A NC | Cable Length N/A 1 m | Function N/A Auxiliary contacts | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT301HF112 | Voltage N/A 24 VAC/DC | Stroke N/A 4.0 mm | Closing Force N/A 100 N | Running Time N/A 3.5 min | NC/NO N/A NC | Cable Length N/A 1 m | Function N/A Auxiliary contacts | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT311F110 | Voltage N/A 230 VAC | Stroke N/A 6.5 mm | Closing Force N/A 125 N | Running Time N/A 4.5 min | NC/NO N/A NC | Cable Length N/A 1 m | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
Part # N/A AXT311F112 | Voltage N/A 24 VAC/DC | Stroke N/A 6.5 mm | Closing Force N/A 125 N | Running Time N/A 4.5 min | NC/NO N/A NC | Cable Length N/A 1 m | Function N/A | CAD N/A |
RFA
N/A AXT 301_311 |
Data Sheet
N/A Open |
© 2021 Fr. SAUTER AG
All rights reserved
SAUTER Head Office
Fr. Sauter AG
Im Surinam 55 | CH-4058 Basel
SAUTER Controls GmbH
Hans-Bunte-Str. 15 | 79108 Freiburg