SAUTER Building Information Modeling
How energy efficiency is improved
Individual setting of occupancy and absence as well as room setpoint correction, control of lights and window blinds for optimum energy usage in the room. Visualisation of the local energy consumption by means of multicolour LED indicator.

Features
  • Part of the SAUTER EY-modulo system family
  • Room operating unit for ecos311, 500, 502, 504, 505 and ASV2
  • Local, intuitive operation for temperature, fan and occupancy
  • Large backlit (BL) display for status information on the room condition
  • Ergonomic push-buttons with mechanical, tactile feedback
  • Individual adjustment of the room climate via temperature detection and setpoint adjustment
  • Operating mode can be set for room occupancy and actuation of a 3-speed fan
  • ECO button for resetting to automatic mode
  • Multicolour LED indicator for visualisation of energy consumption or as position LED
  • Sturdy surface of front cover
  • Fits into standard frame with 55 x 55 mm aperture
  • Individually labelled buttons as accessories
  • Expandable with EY-SU 358 switching unit for operating lights, window blinds etc.
  • Frame can be ordered as an accessory
  • Room operating unit with various functions, designs and colours
1 - 11 of 11 | Results Per Page |   | Unit of Measure
1 

Part #

Color

Sensor Type

Buttons

CAD

RFA

Data Sheet

N/A EY-RU355F002 N/A traffic white N/A NTC N/A No buttons supplied N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355FA02 N/A jet black N/A NTC N/A No buttons supplied N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F021 N/A traffic white N/A NTC N/A + , − , _ , _ , _ N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F031 N/A traffic white N/A NTC N/A + , − , _ , _ , PRA N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F032 N/A traffic white N/A NTC N/A + , − , _ , FAN , _ N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F041 N/A traffic white N/A NTC N/A + , − , _ , FAN , PRA N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F051 N/A traffic white N/A NTC N/A + , − , ECO , FAN , PRA N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355FA51 N/A jet black N/A NTC N/A + , − , ECO , FAN , PRA N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F052 N/A traffic white N/A NTC N/A + , − , UP , DOWN , PRA N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F053 N/A traffic white N/A NTC N/A + , − , UP , DOWN , LIGHT N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
N/A EY-RU355F054 N/A traffic white N/A NTC N/A + , − , ECO , FAN , °C/°F N/A CAD Icon (for items table) N/A Revit Icon (for items table) N/A Open
1 - 11 of 11 | Results Per Page |   | Unit of Measure