Room automation station -EY-RC 504/505
Controls
How energy efficiency is improved
Powerful function modules in the ecos504/505 integrate the regulation of the room temperature, lighting and sunshading to create a comfortable room climate with minimum energy consumption
Features
Powerful function modules in the ecos504/505 integrate the regulation of the room temperature, lighting and sunshading to create a comfortable room climate with minimum energy consumption
Features
- Part of the SAUTER modulo 5 system family
- Modular room automation station (AS) for up to eight rooms or eight flexible room segments
- BACnet/IP communication (EN ISO 164845) as BACnet Building Controller (B-BC)
- The ecoUnit 3 and ecoUnit 1 room operating units enable individual adjustment of the room climate
- Optimises energy consumption thanks to presence function, window contact monitoring, demand
- controlled ventilation, control of lighting and window blinds, and time-dependent setpoint specification
- Function libraries for climate, lighting and sunshading
- Expansion bus for remote ecoLink modules, ecoUnit room operating units and EnOcean wireless interface
- KNX interface to connect KNX operating units, sensors and actuators
- Integrated KNX tunnelling function (KNX/IP) for the commissioning of KNX with ETS
- DALI interface with DALI bus power supply for the connection of DALI electronic ballasts (EB) and DALI sensors
- Web-based commissioning tool for DALI network
- SMI interface (SMI/SMI LoVo) for activating SMI motors for sunshading (window blinds, roller shutters)
- Integrated tunnelling function for commissioning with SMI-easyMonitor
- RS‑485 half duplex, electrically isolated interface for Modbus/RTU, Modbus/ASCII
- Baud rate 600 to 115,200 bit/s with configurable RS‑485 network resistors
- Modbus master with up to four simultaneous communication profiles
- Integrated tunnelling function for commissioning and monitoring with serial Modbus master tools
- Physical M-Bus interface and RS‑232 interface for external M-Bus level converters
- Supports M-Bus baud rates of 300 to 38,400 bit/s
- M-Bus master function with up to four simultaneous communication profiles
- Integrated tunnelling function for commissioning and monitoring with M-Bus tools
- Time programme and calendar function; data recording
- Integrated moduWeb web server (EY‑RC504F101 only)
- Integrated (EY‑RC504F202 only) or licensable MQTT functionality (MQTT Broker / Client)
- Engineering/programming using SAUTER CASE Suite (based on IEC 61131-3)
- Integration into the building management system via BACnet/IP with Ethernet interface
Part # |
IP Interface |
COM1 |
COM2 |
COM3 |
CAD |
RFA |
Data Sheet |
---|---|---|---|---|---|---|---|
Part # N/A EY-RC504F001 | IP Interface N/A BACnet/IP | COM1 N/A | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F101 | IP Interface N/A Bacnet/IP, moduWeb | COM1 N/A | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F202 | IP Interface N/A BACnet/IP, MQTT | COM1 N/A | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F011 | IP Interface N/A BACnet/IP | COM1 N/A KNX | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F021 | IP Interface N/A BACnet/IP | COM1 N/A DALI | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F041 | IP Interface N/A BACnet/IP | COM1 N/A SMI | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F0C1 | IP Interface N/A BACnet/IP | COM1 N/A RS-485 | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC504F0D1 | IP Interface N/A BACnet/IP | COM1 N/A M-Bus | COM2 N/A | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F031 | IP Interface N/A BACnet/IP | COM1 N/A KNX | COM2 N/A DALI | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F051 | IP Interface N/A BACnet/IP | COM1 N/A SMI | COM2 N/A DALI | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F061 | IP Interface N/A BACnet/IP | COM1 N/A KNX | COM2 N/A SMI | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F071 | IP Interface N/A BACnet/IP | COM1 N/A KNX | COM2 N/A SMI | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F081 | IP Interface N/A BACnet/IP | COM1 N/A | COM2 N/A DALI | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F091 | IP Interface N/A BACnet/IP | COM1 N/A SMI | COM2 N/A SMI | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0A1 | IP Interface N/A BACnet/IP | COM1 N/A KNX | COM2 N/A DALI | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0B1 | IP Interface N/A BACnet/IP | COM1 N/A SMI | COM2 N/A SMI | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0E1 | IP Interface N/A BACnet/IP | COM1 N/A RS-485 | COM2 N/A M-Bus | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0F1 | IP Interface N/A BACnet/IP | COM1 N/A RS-485 | COM2 N/A DALI | COM3 N/A | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0G1 | IP Interface N/A BACnet/IP | COM1 N/A RS-485 | COM2 N/A SMI | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0H1 | IP Interface N/A BACnet/IP | COM1 N/A KNX | COM2 N/A RS-485 | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |
Part # N/A EY-RC505F0J1 | IP Interface N/A BACnet/IP | COM1 N/A RS-485 | COM2 N/A DALI | COM3 N/A DALI | CAD N/A | RFA N/A |
Data Sheet
N/A Open |